portable flare stack rentals - one of Western Canada's largest flare stack rental inventories

Portable Flare Stack Rentals Alberta, SK, BC and Western Canada

Portable flare stack rentals in Alberta, SK, BC and Western Canada - OSY supplies field-ready 3 inch to 16 inch flare stacks from 40 feet to 110 feet tall, including guyed, self-supporting, and integral knockout configurations with pilot, ignition, arrestor, anchor, and baseplate options for portable flare stack rentals.

3 inch to 16 inchdiameter range
40 foot to 110 footstack height range
Guyed or self-supportingunit dependent
Pilots and arrestorsaccessories available
Typical dispatch and deployment is often 24-72 hours depending on inventory, unit configuration, job requirements, and location.
Portable flare stack rentals in Alberta and Saskatchewan - OSY Rentals trailer mounted flare stack
Availability and Fit

Portable Flare Stack Rentals - Common Sizes and Configurations

OSY Rentals carries a wide range of flare stack options for temporary production, well testing, flowback support, separator packages, and remote oilfield sites. The right unit depends on tie-in size, expected gas volume, site layout, ignition requirements, and whether the flare stack needs to be paired with other rental equipment.

Flare stacks are commonly rented with knockouts, separators, and vapour-tight tanks when a site needs a more complete temporary production package.

Project planning should also account for applicable local regulations, site conditions, emissions requirements, and operator approval or notification obligations. OSY supplies equipment options and practical rental support, while site-specific compliance remains the operator's responsibility.

Diameter
3 inch to 16 inch flare stack options, unit dependent.
Height
40 foot to 110 foot units available, unit dependent.
Configurations
Guyed, self-supporting, and integral knockout flare stack options.
Accessories
Pilot systems, ignition systems, flame arrestors, detonation arrestors, anchors, baseplates, and related field accessories, unit dependent.
Service Area
Alberta, Saskatchewan, BC, and other Western Canada oilfield locations.
Typical Stock

Portable Flare Stack Rentals - Typical Stock Examples

Common flare stack rental examples

  • 4 inch x 40 footPortable flare stack on trailer
  • 4 inch x 40 footGuyed or self-supporting flare stack, unit dependent
  • 4 inch x 40 footWith 24 inch x 5 foot integral knockout, unit dependent
  • 4 inch x 40 foot dual stackWith 2 inch low pressure riser, unit dependent
  • 6 inch x 40 footSelf-supporting flare stack, unit dependent
  • Additional inventoryOther sizes and configurations available based on current fleet

Why operators prefer OSY Rentals for flare stack rentals in Western Canada

  • Large rental inventoryOne of Western Canada's largest flare stack rental inventories helps OSY match the unit size and configuration to the actual site requirement.
  • Better project fitRenting helps operators avoid forcing owned equipment into a job where a different flare stack, height, ignition option, or accessory package may be a better fit.
  • Package coordinationOSY can coordinate flare stacks with knockouts, separators, and vapour-tight tank packages when a site needs more than one piece of rental equipment.
  • Superior technical supportOperators can discuss stack configuration, pilot systems, ignition options, arrestors, and setup accessories with a rental team focused on oilfield production equipment.
  • Efficiency and cost controlRental equipment can support enhanced operational efficiency and cost-effectiveness when project duration, production conditions, or equipment needs are uncertain.
Field Setup Video

Delivery and Set Up of Rental Flare Stack in Alberta

Inventory Views

Portable Flare Stack Rentals - Inventory and Field Examples

Portable flare stacks rental alberta, saskatchewan, BC, Western Canada - Inventory of dismantled rental flare stacks resting on pipe racks in a snowy Western Canadian oilfield.
Flare stacks for rent
guyed rental flare stacks in alberta - Fully erected guy-wired rental flare stack complete with knockout drum and pilot gas setup in an Alberta oilfield.
Guy-wired rental flare stack with knockout drum in Alberta
portable flare stack rentals - Durable, wind-resistant flare stack pilot burner tip engineered for harsh weather conditions in Western Canada
Durable, wind-resistant flare stack pilot burner tip engineered for harsh weather conditions in Western Canada
Short Video

How Portable Flare Stack Rentals Work

After upstream equipment has done its job, the remaining gas still needs a controlled combustion path. This short video gives a simple overview of how an OSY flare stack helps move gas through a self-supporting riser, always-lit pilot system, and flare tip.

A Simple Look at the Flare Stack's Role

A flare stack is used after upstream equipment has separated or controlled the flow enough for gas to be safely routed to combustion. For field planning, OSY can help confirm the stack size, configuration, pilot or ignition option, and accessory requirements for the job.

For broader rental packages, ask about pairing a flare stack with a knockout, separator, or vapour-tight tank.

Technical Support Equipment

Portable Flare Stack Rentals - Pilot, Ignition, Arrestors, and Accessories

Pilot and Ignition Systems

OSY Rentals carries all three types of Tornado Pilot and Ignition systems, which include:

  • Propane or natural gas pilots
  • Electronic ignitions in 12V, 24V or 120V
  • Constant pilots with auto relight in 12V, 24V or 120V

Both the pilot and ignition systems are mounted on a tracking system. Having the ability to winch the unit up and down the flare stack makes for easy inspection and maintenance.

Close-up of a flare stack burner tip with attached pilot line and spark ignition assembly for rent in Alberta, SK, BC, Western Canada
Flare stack burner tip with attached pilot line and spark ignition assembly
Remote flare stack pilot control panel with auto-ignition and flame monitoring features, available for rent for oilfields in AB, SK, BC, Western Canada.
Remote flare stack pilot control panel with auto-ignition and flame monitoring
High-voltage ignition transformer box mounted on a Tornado rental flare stack in Alberta.
High-voltage ignition transformer box mounted on a Tornado rental flare stack

Flame Arrestors and Detonation Arrestors

Detonation arrestors are tested to CSA Z343-98 and are designed to withstand up to two hours of continuous burn. Cells can easily be cleaned and return to like-new condition.

The flame arrestors are the industry standard for crimped ribbon flame arrestors and are available in aluminum, 304L stainless steel, and 316L stainless steel. Cells can be cleaned to like-new condition.

Tornado inline flame arrestor rental for oilfield flare stack systems, available for rent in Alberta, SK, BC, Western Canada.
Tornado inline flame arrestor available for rent

Remote Power and Setup Accessories

Remote sites may need additional support such as solar power skids, anchors, baseplates, and other field setup accessories. Availability depends on the equipment package and current inventory.

  • Portable solar power skids for select remote applications
  • Anchors and baseplates for setup support
  • Accessory coordination for temporary production packages
Portable solar power skids for off-grid flare stack ignition and monitoring systems rental in remote oilfield locations.
Portable solar power skids for off-grid flare stack ignition and monitoring systems
Use Cases

Portable Flare Stack Rentals for Temporary Oilfield Operations

Common Rental Applications

  • Temporary production setups
  • Well testing and flowback support
  • Separator and test package applications
  • Remote oilfield sites requiring temporary gas handling
  • Short-term or transitional facility requirements
  • Projects where renting is more practical than purchasing

Information to Share When Requesting Availability

  • Project location and required timeline
  • Tie-in size and expected application
  • Preferred flare stack height or configuration, if known
  • Whether ignition, pilot, arrestor, anchor, or baseplate accessories are required
  • Whether you also need a knockout, separator, or tank package
Frequently Asked Questions

Portable Flare Stack Rentals - Frequently Asked Questions

What is a portable flare stack and when do I need one?

A portable flare stack is used to combust waste gas in a controlled way instead of venting it raw. Operators commonly use flare stacks for temporary production, well testing, maintenance, flowback support, separator service, upset conditions, and other short-term field operations where stable combustion is possible and conservation or permanent gas handling is not available.

Sources: AER Directive 060 - BCER Flaring and Venting Reduction Guideline

Should I use an open flare or an enclosed combustor/incinerator?

Use an enclosed unit when the project requires lower visibility, reduced light, or reduced noise near people or sensitive receptors. Use an open flare for temporary high-rate burns where setbacks, visibility, gas characteristics, and site conditions make it appropriate. Final selection depends on H2S and hydrocarbon content, expected flow, heat release, ambient air quality objectives, nearby receptors, and project-specific regulatory requirements.

Sources: AER Directive 060 - BCER Guideline

What flare stack sizes does OSY Rentals commonly carry?

OSY Rentals commonly supplies flare stack rentals from 3 inch to 16 inch diameter and from 40 foot to 110 foot height, depending on the unit and application.

What configurations are available?

Available configurations can include guyed flare stacks, self-supporting flare stacks, and integral knockout flare stack options. Availability depends on current fleet inventory and job requirements.

What approvals and notifications are required in Alberta and BC?

Approval, notification, and reporting requirements depend on the province, project type, duration, gas composition, volumes, nearby receptors, and whether the event is routine or non-routine. Alberta operators should review AER Directive 060 and applicable AER guidance. BC operators should review the BCER Flaring and Venting Reduction Guideline. OSY can support equipment planning, but operator compliance, notifications, and approvals remain site-specific responsibilities.

Sources: AER Directive 060 - BCER Guideline

How do H2S and odour affect flare setup?

Gas composition matters. If gas contains H2S or odorous compounds, project planning may need to consider odour control, ambient air objectives, combustion reliability, ignition reliability, nearby receptors, and whether an enclosed combustion option is more appropriate. Operators should confirm the applicable regulatory and engineering requirements for the site.

What site constraints and setbacks should I plan for?

Plan for safe separation from people, equipment, roads, ignition sources, and nearby receptors. Lease layout, heat radiation, stack height, guy wire space, wind exposure, access, and emergency planning can all affect the flare stack configuration. Site-specific engineering and regulatory requirements should be confirmed before operation.

How are combustion efficiency, visible smoke, and air quality addressed?

Combustion planning should account for gas composition, heating value, expected flow range, equipment configuration, ambient air objectives, nearby receptors, and visible emissions. If black smoke, odour, or poor combustion is likely, the operator may need mitigation, equipment changes, additional separation, an enclosed combustion option, or additional technical review.

Sources: AER Directive 060 - BCER Guideline

When is venting allowed instead of flaring?

Venting is generally discouraged when gas can be conserved or combusted safely. Whether venting is allowed depends on jurisdiction, safety, equipment reliability, gas characteristics, economics, and the specific regulatory requirements for the event. Operators should review AER Directive 060 in Alberta and BCER guidance in BC before choosing venting over flaring or incineration.

Sources: AER Directive 060 - BCER Guideline

Do you provide pilot and ignition system options?

Yes. OSY Rentals carries Tornado Pilot and Ignition systems, including propane or natural gas pilots, electronic ignition options in 12V, 24V or 120V, and constant pilots with auto relight in 12V, 24V or 120V, unit dependent.

Do you have flame arrestors and detonation arrestors available?

Yes. OSY Rentals can supply related accessories such as flame arrestors and detonation arrestors, depending on the equipment package and project requirements.

How do separators and knockouts improve flare performance?

Separators and knockouts help remove liquids and stabilize flow before gas reaches the flare stack. This can help protect the stack, reduce surge, support cleaner combustion, and improve overall rental package performance. OSY often pairs flare stacks with separators and knockouts when the site requires upstream separation or liquids handling.

Can flare stacks be supplied with other rental equipment?

Yes. Portable flare stack rentals are often supplied with knockouts, separators, and vapour-tight tanks as part of a temporary production or testing package.

What information do you need from me to size a rental flare package?

Share the project location, start date, expected duration, tie-in size, expected flow range, gas composition if available, pressure and temperature, H2S information, site constraints, nearby receptors, and whether you need supporting equipment such as a separator, knockout, hose, manifold, or tank package.

Request a sizing and quote

What records and reporting should operators expect?

Recordkeeping and reporting requirements depend on the jurisdiction and the event. Operators may need to track dates, locations, volumes, reduction measures, event type, gas composition, modelling, complaints, and other site-specific details. Alberta operators should review AER Directive 060 and AER reporting expectations. BC operators should review BCER guidance and applicable reporting processes.

Sources: AER flaring and venting topic - BCER Guideline

How quickly can OSY Rentals dispatch a flare stack?

Typical dispatch and deployment is often 24-72 hours, depending on inventory availability, job requirements, transportation, and site location. Share your location, timing, and required configuration so OSY can confirm suitable options.

Can portable flare stack rentals be used in remote locations?

Yes. OSY Rentals serves remote oilfield locations across Alberta, Saskatchewan, BC, and Western Canada. Remote sites may require additional support items such as ignition accessories, anchors, baseplates, or off-grid power components.

What areas does OSY Rentals serve for flare stack rentals?

OSY Rentals serves flare stack rental needs across Alberta, Saskatchewan, BC, and other Western Canada project areas.

Related Equipment

Related Oilfield Rental Equipment

Need Portable Flare Stack Rentals in Western Canada?

Tell us your project location, timing, tie-in size, and any related equipment needs. OSY Rentals can help confirm suitable flare stack rental options and package support for your site.